Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of Korean Medical Science ; : 294-302, 2001.
Article in English | WPRIM | ID: wpr-62733

ABSTRACT

Feasibility of identifying viable myocardium in rest and stress magnetic resonance imaging (MRI) was evaluated using 3 hr occlusion and 30 min reperfusion model of left anterior descending (LAD) coronary artery in 12 felines. At rest MRI, viable myocardium confirmed by 2,3,5-triphenyl tetrazolium chloride (TTC)- staining showed rapid signal intensity (SI) rise followed by gradual decline not significantly different from normal myocardium that the two hyperperfused regions were distinguishable only from the hypoperfused nonviable myocardium. At stress MRI, hyperemia induced perfusion change was most pronounced in normal myocardium with earlier and greater peak enhancement followed by brisk 'washout' phase while minimally augmented enhancement in viable myocardium was still in 'washin' phase. From these findings, it was concluded that viable myocardium is identified in rest and stress MRI as redistributing hypo- perfusion compared to persistent hyper-perfusion of the normal myocardium and the persistent hypo-perfusion of the nonviable myocardium.


Subject(s)
Cats , Animals , Heart/diagnostic imaging , Hyperemia/diagnostic imaging , Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Myocardial Reperfusion Injury/diagnostic imaging , Stress, Physiological
2.
Journal of Korean Medical Science ; : 139-145, 2000.
Article in English | WPRIM | ID: wpr-18580

ABSTRACT

To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR.


Subject(s)
Adult , Aged , Female , Humans , Male , Blood Flow Velocity , Comparative Study , Coronary Angiography , Coronary Circulation , Coronary Disease/diagnostic imaging , Echocardiography, Doppler/standards , Echocardiography, Doppler/methods , Heart Rate , Hyperemia/diagnostic imaging , Linear Models , Middle Aged , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL